Skip to main content

Customising reports

MultiQC offers a few ways to customise reports to easily add your own branding and some additional report-level information. These features are primarily designed for core genomics facilities.

Note that much more extensive customisation of reports is possible using custom templates.

Titles and introductory text

You can specify a custom title for the report using the -i/--title command line option. The -b/--comment option can be used to add a longer comment to the top of the report at run time.

You can also specify the title and comment, as well as a subtitle and the introductory text in your config file:

title: "My Title"
subtitle: "A subtitle to go underneath in grey"
intro_text: "MultiQC reports summarise analysis results."
report_comment: "This is a comment about this report."

Note that if intro_text is None the template will display the default introduction sentence. Set this to False to hide this, or set it to a string to use your own text.

Report time and analysis paths

It's not always appropriate to include the file paths that MultiQC was run with in a report, for example, if sharing reports with others outside your organisation.

If you wish, you can disable the analysis paths and/or time in the report header with the following config parameters:

show_analysis_paths: False
show_analysis_time: False

To add your own custom logo to reports, you can add the following three lines to your MultiQC configuration file:

custom_logo: "/abs/path/to/logo.png"
custom_logo_url: "https://www.example.com"
custom_logo_title: "Our Institute Name"

Only custom_logo is needed. The URL will make the logo open up a new web browser tab with your address and the title sets the mouse hover title text.

Project level information

You can add custom information at the top of reports by adding key:value pairs to the config option report_header_info. Note that if you have a file called multiqc_config.yaml in the working directory, this will automatically be parsed and added to the config. For example, if you have the following saved:

report_header_info:
- Contact E-mail: "phil.ewels@seqera.io"
- Application Type: "RNA-seq"
- Project Type: "Application"
- Sequencing Platform: "HiSeq 2500 High Output V4"
- Sequencing Setup: "2x125"

Then this will be displayed at the top of reports:

report project info

Note that you can also specify a path to a config file using -c.

Listing software versions

If a software tool prints its version number in log output, MultiQC attempts to find this information and print it in reports (see Saving version information) for module developer documentation. However, not all tools make version information available in their log files. Additionally, some situations may require bespoke version number reporting, for example if software is found within multiple scopes in an analysis pipeline.

In these cases, you can manually add software version information to a report. This can be done in two different ways: by adding them into the MultiQC configuration, or by creating stand-alone YAML files with specific filenames and formats.

Both methods have the same syntax for the YAML configuration, with the exception of MultiQC configuration files requiring a top-level software_versions. The examples below are for a MultiQC config file.

If a provided software name exactly matches the name of a module that ran (case insensitive), then the version number(s) will be shown alongside the section heading. All software versions will be printed at the bottom of the report. This is the same behaviour as version numbers found within log files.

Option 1: Dictionary of software name and version pairs

The simplest way to provide version numbers is to give names and versions:

software_versions:
samblaster: "0.1.24"
quast: "5.2.0"

Make sure that you write the version in quotes to ensure it is being interpreted as a string. For example, a version 1.10 without quotes would be parsed as a float and displayed as version 1.1.

If you have run a tool multiple times and have multiple software versions, you can provide a list of versions:

software_versions:
samblaster: "0.1.24"
quast:
- "5.2.0"
- "5.1.0"

Option 2: Grouping software and versions

In more complex scenarios, you may have multiple version names that you want to group. For example, a tool that wraps other tools, or listing software version numbers grouped by analysis pipeline step.

Here, input is provided as a nested YAML dictionary with three levels: group -> software(s) -> version(s).

software_versions:
samtools:
samtools: "1.11"
htslib: "1.3"
quast:
quast:
- "5.2.0"
- "5.1.0"
software_versions:
analysis_stage_1:
samtools: "1.3"
htslib: "1.3"
analysis_stage_2:
samtools: "1.11"
htslib: "1.11"
analysis_stage_3:
quast:
- "5.2.0"
- "5.1.0"

If a group and software have the same name (eg. samtools -> samtools), the software name will not be repeated in the section header.

Software versions YAML file

If you prefer to provide versions in a separate YAML file, MultiQC will also look for filenames ending in *_mqc_versions.(yml|yaml) in your search path, for example rnaseq_mqc_versions.yml or mapping_mqc_versions.yaml. The content of these YAML files should be a YAML dictionary, similar to the previous examples but without the top level software_versions. For example:

samblaster: "0.1.24"
quast:
- "5.2.0"
- "5.1.0"
some_other_tool: "2023-1"

If multiple YAML files are found the content of these will be merged together.

Disabling automatic versions

In some applications, such as a pipeline workflow, you may wish to only include version information defined in the config file or in a separate YAML file. For this, it possible to disable parsing versions from the log file through the following config option:

disable_version_detection: true

Disabling software version report section

If you like, you can remove the Software Versions report section. Software versions will still be shown inline with the headings, where possible. To do this, use the following config option:

skip_versions_section: true

Note that setting this in combination with manually added version numbers could lead to versions not being included within the report.

Customize software versions table header

In the Software Versions report section the default table header for the column, listing groups of software, is "Group". This can be changed by setting the config option versions_table_group_header to your desired header name. For example:

versions_table_group_header: "Analysis Pipeline Step"

Sample name replacement

Occasionally, when you run MultiQC you may know that you want to change the resulting sample names at run time. You can do this using the --replace-names option, which allows you to change sample names during report creation.

Unlike --sample-names below, the original names never make it through to the report. This can be useful if you know that you have a range of outputs that result in varying sample names but want to create a consistent report - especially if you want samples to line up properly in the General Statistics table.

To use, create a tab-separated file with two columns. The first column contains the search strings and the second the replacement strings:

IDX102934	Sample_1
IDX102935 Sample_2
IDX102936 Sample_3

Note that by default, partial matches are replaced. So if a log file gives a sample name of IDX102934_mytool then the result will be Sample_1_mytool. There are two config options to fine-tune this behaviour:

Setting sample_names_replace_exact to True in a MultiQC config file will tell MultiQC to only change a sample name if the pattern fully matches the search string. In the above example, IDX102934_mytool would remain unchanged.

Setting sample_names_replace_complete to True, the replacement string will be used as a complete replacement if the search pattern matches at all. In the above example, IDX102934_mytool would become Sample_1.

Use this method with caution! If aggressive cleaning of sample names results in multiple samples with identical identifiers, they will be overwritten.

To have more control over replacements, you can use regular expressions. If you set sample_names_replace_regex to True in a MultiQC config file and then create a file that contains regex search strings and even Python regex group identifiers in the replace string. For example:

SAMPLE(\d)_([PS]E)_(\d)	XXX_\1_\2_\3

With this file, SAMPLE1_PE_2 would be renamed to XXX_1_PE_2. SAMPLE3_SE_4 would be renamed to XXX_3_SE_4.

Setting sample_names_replace_exact to True also works for regular expression searches. The code uses the re.fullmatch function, so no ^ or $ anchors are needed.

Setting sample_names_replace_complete is ignored when using regexes. If you want this behaviour then configure your regular expression to match the entire string. For example, *(\d)_([PS]E)_(\d) \1_\2_\3 would rename SAMPLE1_PE_2 to 1_PE_2.

Finally, if you prefer not to use --replace-names with a TSV file, you can set the search patterns in a MultiQC config file directly. For example:

sample_names_replace:
IDX102934: Sample_1
IDX102935: Sample_2
IDX102936: Sample_3

Remember that backslashes must be escaped in YAML. So if using regular expressions you will need to use double-backslashes. You may also need to quote strings:

sample_names_replace_regex: True
sample_names_replace:
"SAMPLE(\\d)_([PS]E)_(\\d)": "XXX_\\1_\\2_\\3"

Bulk sample renaming in reports

Although it is possible to rename samples manually and in bulk using the report toolbox, it's often desirable to embed such renaming patterns into the report so that they can be shared with others. For example, a typical case could be for a sequencing centre that has internal sample IDs and also user-supplied sample names. Or public sample identifiers such as SRA numbers as well as more meaningful names.

It's possible to supply a file with one or more sets of sample names using the --sample-names command line option. This file should be a tab-delimited file with a header row (used for the report button labels) and then any number of renamed sample identifiers. For example:

MultiQC Names	Proper Names	AWESOME NAMES
SRR1067503_1 Sample_1 MYBESTSAMP_1
SRR1067505_1 Sample_2 MYBESTSAMP_2
SRR1067510_1 Sample_3 MYBESTSAMP_3

If supplied, buttons will be generated at the top of the report with your labels. Clicking these will populate and apply the Toolbox renaming panel.

Sample renaming works with partial substrings - these will be replaced!

It's also possible to supply such renaming patterns within a config file (useful if you're already generating a config file for a run). In this case, you need to set the variables sample_names_rename_buttons and sample_names_rename. For example:

sample_names_rename_buttons:
- "MultiQC Names"
- "Proper Names"
- "AWESOME NAMES"
sample_names_rename:
- ["SRR1067503_1", "Sample_1", "MYBESTSAMP_1"]
- ["SRR1067505_1", "Sample_2", "MYBESTSAMP_2"]
- ["SRR1067510_1", "Sample_3", "MYBESTSAMP_3"]

Show / Hide samples buttons

It is possible to filter which samples are visible through the report toolbox, but it can be desirable to embed such patterns into the report so that they can be shared with others. One example can be to add filters for batches, to easily scan if certain quality metrics overlap between these batches.

It's possible to supply a file with one or more patterns to filter samples on using the --sample-filters command line option. This file should be a tab-delimited file with each row containing the button name, whether the pattern should be hidden (hide) or shown (show) and the patterns to be applied (all subsequent columns). If you want to use a regular expression pattern, opposed to the default globbing, you can use hide_re and show_re.

For example, to filter on read pair groups, you could use the following file:

Read Group 1	show	_R1
Read Group 2 show _R2

Or in regex mode:

Read Group 1	show_re	.*_R1
Read Group 2 show_re .*_R2

To filter on controls and sample groups you could use:

Controls	show	input_
Conditions show group_1_ group_2_ group_3_

MultiQC automatically adds an Show all button at the start, which reverts back to showing all samples.

If you prefer, you can also add these buttons using a MultiQC config file:

show_hide_buttons:
- Read Group 1
- Read Group 2
- Controls
- Conditions
show_hide_mode:
- show
- show
- show
- show
show_hide_patterns:
- _R1
- _R2
- input_
- ["group_1_", "group_2_", "group_3_"]

Module and section comments

Sometimes you may want to add a custom comment above specific sections in the report. You can do this with the config option section_comments as follows:

section_comments:
featurecounts: "This comment is for a module header, but should still work"
star_alignments: "This new way of commenting above sections is **awesome**!"

Comments can be written in Markdown. The section_comments keys should correspond to the HTML IDs of the report section. You can find these by clicking on a navigation link in the report and seeing the #section_id at the end of the browser URL.

To add a section comment for General Statistics, use the ID general_stats.

Removing modules or sections

If you don't want an entire module to be used in a MultiQC report, use the -e/--exclude command line flags to skip running that tool. You can also use the config option exclude_modules:

exclude_modules:
- fastqc
- cutadapt

If you want to run only specific modules, you can do that with -m/--module or the config option run_modules:

run_modules:
- fastqc
- cutadapt

If you would like to remove just one section of a module report, you can do so with the remove_sections config option as follows:

remove_sections:
- section-id-one
- second-section-id

The section ID is the string appended to the URL when clicking a report section in the navigation.

For example, the GATK module has a section with the title "Compare Overlap". When clicking that in the report's left-hand side navigation, the web browser URL has #gatk-compare-overlap appended. Here, you would add gatk-compare-overlap to the remove_sections config.

Finally, you can prevent MultiQC from finding the files for a module or submodule by customising its search pattern. For example, to skip Picard Base Calling metrics, you could use the following:

sp:
picard/collectilluminabasecallingmetrics:
skip: true

The search pattern identifiers can be found in the documentation below for each module.

Removing General Statistics

The General Statistics is a bit of a special case in MultiQC, but there is added code to make it behave well with the above mechanism. On the command line, you can specify -e general_stats. Alternatively, you can set the following config flag in your MultiQC config:

skip_generalstats: true

Order of modules

By default, modules are included in the report as in the order specified in config.module_order. Any modules found which aren't in this list are appended at the top of the report.

Top modules

To specify certain modules that should always come at the top of the report, you can configure config.top_modules in your MultiQC configuration file. For example, to always have the FastQC module at the top of reports, add the following to your ~/.multiqc_config.yaml file:

top_modules:
- "fastqc"

Running modules multiple times

A module can be specified multiple times in either config.module_order or config.top_modules, causing it to be run multiple times. By itself you'll just get two identical report sections. However, you can also supply configuration options to the modules as follows:

top_modules:
- moduleName:
name: "Module (filtered)"
info: "This section shows the module with different files"
path_filters:
- "*_special.txt"
- "*_others.txt"
- moduleName:
name: "Module (not-special)"
path_filters_exclude:
- "*_special.txt"

These overwrite the defaults that are hardcoded in the module code. path_filters and path_filters_exclude being the exception. These filter the file searches for a given list of glob filename patterns:

PatternMeaning
*matches everything
?matches any single character
[seq]matches any character in seq
[!seq]matches any character not in seq

Note that exclusion superseeds inclusion for the path filters.

The other available configuration options are:

  • name: Section name
  • anchor: Section report ID
  • target: Intro link text
  • href: Intro link URL
  • info: Intro text
  • extra: Additional HTML after intro.
  • custom_config: Custom module-level settings. Translated into config.moduleName, but specifically for this section.

For example, to run the FastQC module twice, before and after adapter trimming, you could use the following config:

module_order:
- fastqc:
name: "FastQC (trimmed)"
anchor: "fastqc_trimmed"
info: "This section of the report shows FastQC results after adapter trimming."
target: ""
path_filters:
- "*_1_trimmed_fastqc.zip"
- cutadapt
- fastqc:
name: "FastQC (raw)"
anchor: "fastqc_raw"
path_filters:
- "*_1_fastqc.zip"

Note that if you change the name then you will get multiples of columns in the General Statistics table. If unchanged, the topmost module may overwrite output from the first iteration.

If you set a custom anchor, then this can be used for other configuration options. For example, using the anchors above and the report_section_order described below:

report_section_order:
fastqc_trimmed:
before: fastqc_raw

Currently, you can not list a module name in both top_modules and module_order. Let me know if this is a problem..

Order of module and module subsection output

The module_order config changes the order in which each MultiQC module is executed. However, sometimes it's desirable to customise the order of specific sections in a report, independent of the order of module execution. For example, the custom_content module can generate multiple sections from different input files. Also, module_order does not allow you to change the sequence of sections within a MultiQC module.

To change the order of MultiQC outputs, follow a link in a report navigation to skip to the section you want to move (either a major section header or a subheading). Find the ID of that section by looking at the URL. For example, clicking on FastQC changes the URL to multiqc_report.html#fastqc - the ID is the text after (not including) the # symbol: fastqc. The FastQC Status Checks subsection is multiqc_report.html#fastqc_status_checks and has the id fastqc_status_checks.

Next, specify the report_section_order option in your MultiQC config file. Modules and sections in the report are given a number ranging from 10 (section at bottom of report), incrementing by +10 for each section. You can change this number (eg. a very low number to always get at the bottom of the report or very high to always be at the top), or you can move a section to before or after another existing section (has no effect if the other named ID is not in the report).

Note that module sub-sections can only be move within their module. So you can't have the FastQC Adapter Content section shown under the GATK module header.

You can also use this config option to completely remove module sub-sections. To do this, just set the subsection ID to remove (NB: no : or -). This only works for module subsections. To remove an entire module, use the -e/--exclude flag.

For example, you could add the following to your MultiQC config file:

report_section_order:
module_output_1:
order: -1000
module_output_2:
after: "diffsection"
mod_section_1:
before: "othersection"
mod_section_2: remove

Customising plots

Almost every plot in all MultiQC reports are created using standard plotting functions and a plot config. You can override any plot config variable you like for any plot to customise how these are generated.

To do this, first find the plot that you would like to customise and copy it's unique ID. You can find this by clicking export - the name next to the checkbox is the ID.

Next, you need to find the plot config key(s) that you would like to change. You can find these by reading the MultiQC documentation below.

For example, to set a new limit for the Picard InsertSizeMetrics x-axis, you can use the following:

custom_plot_config:
picard_insert_size:
xmax: 300

You can customise multiple variables for multiple plots:

custom_plot_config:
# Show the percentages tab by default for the FastQC sequence counts plot
fastqc_sequence_counts_plot:
cpswitch_c_active: False

# Only show up to 20bp on the x axis for cutadapt, change the title
cutadapt_plot:
xmax: 20
title: "How many base pairs have been removed from the data"

# Add a coloured band in the background to show what is a good result
# Yes I know this doesn't make sense for this plot, it's just an example ;)
bismark_mbias:
yPlotBands:
- from: 0
to: 40
color: "#e6c3c3"
- from: 40
to: 80
color: "#e6dcc3"
- from: 80
to: 100
color: "#c3e6c3"

As of version 1.8, this also works for customising the config of bargraph categories:

custom_plot_config:
bowtie1_alignment:
reads_aligned:
color: "#d84e2f"
multimapped:
color: "#f2e63f"
not_aligned:
color: "#8bbc21"

Customising tables

Much like with the custom plot config above, you can override almost any configuration options for tables. To see what's available, read the documentation about Creating a table.

Tables have configuration at two levels:

  1. Entire table
    • Affects all columns and data. These configs are the same as plot configs and can be overridden with custom_plot_config as described in the Customising plots section.
  2. Specific columns
    • Table columns (headers) have their own configuration scope:custom_table_header_config. See below.

Config for an entire table

Here we are customising the Picard HSMetrics table. We're setting a non-standard title for the first column (usually "Sample name") and changing the minimum value for the colour scale for all columns.

Here min is a header config but we're setting it at table config level. This means it will be used as a default for all columns in the table, overwriting anything that the module defines itself specifically for a given column.

custom_plot_config:
picard_hsmetrics_table:
col1_header: "Identifiers"
min: 1000

Another example of how this can be used is to make all columns in the General Statistics table hidden by default:

custom_plot_config:
general_stats_table:
hidden: true

Config for a specific column

To change the number of decimals used in the General Statistics table for the single column Qualimap: Mean Coverage:

custom_table_header_config:
general_stats_table:
mean_coverage:
format: "{:,.20f}"

The first key is the table ID, the second is the header ID for the column you want to change.

The easiest way to find these IDs is by clicking Configure Columns above the table you want to customise.

Table: configure columns button

The table ID is shown at the top of the modal window. The ID column shows the column (header) ID.

Table: configure columns button

Hiding columns

Report tables such as the General Statistics table can get quite wide. To help with this, columns in the report can be hidden. Some MultiQC modules include columns which are hidden by default, others may be uninteresting to some users.

To allow customisation of this behaviour, the defaults can be changed by adding to your MultiQC config file. This is done with the table_columns_visible value. Open a MultiQC report and click Configure Columns above a table. Make a note of the Group and ID for the column that you'd like to alter. For example, to make the % Duplicate Reads column from FastQC hidden by default, the Group is FastQC and the ID is percent_duplicates. These are then added to the config as follows:

table_columns_visible:
FastQC:
percent_duplicates: False

You can also specify a value for an entire module / table namespace. This will then show or hide all columns for that module. For example:

table_columns_visible:
FastQC: False

Note that you can set these values to True to show columns that would otherwise be hidden by default.

It can also be done for other module-specific tables in the report, where instead of the Group, you'd need to specify the table ID. To get the table ID, click Configure Columns above the table, and look for the first line above the table contents. It should say something like "Uncheck the tick box ... Table ID: quast_table".

For example, to hide the # misassemblies column in the Assembly Statistics table from QUAST, you would use the following config:

table_columns_visible:
quast_table:
"# misassemblies": false

Or you can pass the column ID directly:

table_columns_visible:
"# misassemblies": false

Column order

In the same way, you can force a column to appear at the start or end of the table, or indeed impose a custom ordering on all the columns, by setting the table_columns_placement. High values push columns to the right hand side of the table and low to the left. The default value is 1000. For example:

table_columns_placement:
Samtools:
reads_mapped: 900
properly_paired: 1010
secondary: 1020

In this case, since the default placement weighting is 1000, the reads_mapped will end up as the leftmost column and the other two will and up as the final columns on the right of the table.

The columns are organised by either namespace or table ID, then column ID. In the above example, Samtools is the namespace in the General Statistics table - the text that is at the start of the tooltip. For custom tables, the ID may be easier to use.

Column titles

Sometimes it may be helpful to adjust the default table column header to display a different title. For example when running a module multiple times, or when different modules have columns with similar names.

To do this, use the approach described above to find the column Group and ID and combine with the table_columns_name config option. For example, the following config will change the General Statistics column for FastQC from % GC to Percent of bases that are GC

table_columns_name:
FastQC:
percent_gc: "Percent of bases that are GC"

It will also work for module-specific tables by using the table ID instead of the module name, and specifying the column ID directly. See the Hiding columns section above for more details.

Conditional formatting

It's possible to highlight values in tables based on their value. This is done using the table_cond_formatting_rules config setting. Rules can be applied to every table in the report (all_columns), specific tables (table ID), or specific columns (column ID).

The default rules are as follows:

table_cond_formatting_rules:
all_columns:
pass:
- s_eq: "pass"
- s_eq: "true"
warn:
- s_eq: "warn"
- s_eq: "unknown"
fail:
- s_eq: "fail"
- s_eq: "false"

These make any table cells in the report that match the string pass or true have text with a green background, orange for warn, red for fail and so on. There can be multiple tests for each style of formatting - if there is a match for any, it will be applied. The following comparison operators are available:

  • s_eq - String exactly equals (case insensitive)
  • s_contains - String contains (case insensitive)
  • s_ne - String does not equal (case insensitive)
  • eq - Value equals
  • ne - Value does not equal
  • gt - Value is greater than
  • lt - Value is less than

To have matches for a specific table or column, use that ID instead of all_columns.

For example, for the entire General Stats table:

table_cond_formatting_rules:
general_stats_table:
pass:
- gt: 80
warn:
- lt: 80
fail:
- lt: 70

Or for one column in the General Stats table:

table_cond_formatting_rules:
mqc-generalstats-uniquely_mapped_percent:
pass:
- gt: 80
warn:
- lt: 80
fail:
- lt: 70

Note that the formatting is done in a specific order - pass/warn/fail by default, so that anything matching both warn and fail will be formatted as fail for example. This can be customised with table_cond_formatting_colours (see below).

To find the unique ID for your table / column, right click it in a report and inspect it's HTML (Inpsect in Chrome).

  • Tables should look something like <table id="general_stats_table" class="table table-condensed mqc_table" data-title="General Statistics">, where general_stats_table is the ID.
  • Table cells should look something like <td class="data-coloured mqc-generalstats-Assigned">, where the mqc-generalstats-Assigned bit is the unique ID.

I know this isn't the same method of IDs as above and it isn't super easy to do. Sorry about that!

It's possible to highlight matches in any number of colours. MultiQC comes with the following defaults:

table_cond_formatting_colours:
- blue: "#337ab7"
- lbue: "#5bc0de"
- pass: "#5cb85c"
- warn: "#f0ad4e"
- fail: "#d9534f"

These can be overridden or added to with any string / CSS hex colour combinations you like. You can generate hex colour codes with lots of tools, for example htmlcolorcodes.com

Note that the different sets of rules are formatted in order. So if a value matches both pass and fail then it will be formatted as a fail

Number base (multiplier)

To make numbers in the General Statistics table easier to read and compare quickly, MultiQC sometimes divides them by one million (typically read counts). If your samples have very low read counts then this can result in the table showing counts of 0.0, which isn't very helpful.

To change this behaviour, you can customise three config variables in your MultiQC config. The defaults are as follows:

read_count_multiplier: 0.000001
read_count_prefix: "M"
read_count_desc: "millions"

So, to show thousands of reads instead of millions, change these to:

read_count_multiplier: 0.001
read_count_prefix: "K"
read_count_desc: "thousands"

The same options are also available for numbers of base pairs:

base_count_multiplier: 0.000001
base_count_prefix: "Mb"
base_count_desc: "millions"

And for long reads:

long_read_count_multiplier: 0.001
long_read_count_prefix: "K"
long_read_count_desc: "thousands"

Number formatting

By default, the interactive plots in MultiQC reports use spaces for thousands separators and points for decimal places (e.g. 1 234 567.89). Different countries have different preferences for this, so you can customise the two using a couple of configuration parameters - decimalPoint_format and thousandsSep_format.

For example, the following config would result in the following alternative number formatting: 1234567,89.

decimalPoint_format: ","
thousandsSep_format: ""

This formatting currently only applies to the interactive charts. It may be extended to apply elsewhere in the future (submit a new issue if you spot somewhere where you'd like it).

Bar plot legend positioning

By default, the legend for bar plots is placed on the right hand side of the plot. If you'd like to move it to the bottom, you can use the following config option:

barplot_legend_on_bottom: true

This is not recommended to set up globally though, as it would look well only for medium-sized plot, but would start overlapping with the tick labels on shorter plots, or create a large gap on taller plots.

Troubleshooting

One tricky bit that caught me out whilst writing this is the different type casting between Python, YAML and Jinja2 templates. This is especially true when using an empty variable:

# Python
my_var = None
# YAML
my_var: null
# Jinja2
if myvar is none # Note - Lower case!

Sample grouping

MultiQC does its best to have one row per sample in a table. Some modules, however, may produce multiple results per sample. These will be treated as separate samples alongside the shorter "merged" sample name from downstream steps, resulting in half-empty rows. A prominent example of this is FastQC, that can be run separately for forward and reverse reads:

Table: General Statistics table without sample grouping

To improve how these samples are shown, MultiQC attempts to group such samples. For modules that support this option, MultiQC offers a config option table_sample_merge that maps chunk labels to file name patterns.

For example, to tell MultiQC to group SAMPLE_R1 and SAMPLE_R2 together as SAMPLE, you can specify the following section in the config:

table_sample_merge:
"R1": "_R1"
"R2": "_R2"

For the modules that have only data for SAMPLE_R1 and SAMPLE_R2 - e.g. FastQC - MultiQC will try to trim _R1 and _R1 endings from each name, and merge together the data from both into a virtual sample SAMPLE. It will sum up or weighted average, whatever is relevant for each given statistic.

Table: General Statistics table with sample grouping

Clicking on the row header will expand the row to show the individual chunks data:

Table: General Statistics table with sample groups expanded

More sophisticated patterns are supported such as listing multiple strings, or using regular expression with type: regex:

table_sample_merge:
"Read 1":
- "_R1"
- type: regex
pattern: "[_.-][rR]?1$"
"Read 2":
- "_R2"
- type: regex
pattern: "[_.-][rR]?2$"

The format of supported types is the same as for cleaning extensions option:

  • "truncate": The default mode. To get the group name, remove the pattern from the end of the string.
  • "remove": Remove the pattern from the middle.
  • "regex": Match a regular expression pattern and remove the matched part.
  • "regex_keep": Match a regular expression pattern and keep only the matched part.

Each module must be configured to use this config option. If you find a MultiQC module that doesn't use this config yet, please help us by implementing it for a new module and submitting a pull request, or create an issue.

This only works for tables, and doesn't affect plots. You might want to combine this option with module_order to repeat the module in the report for each grouping criteria, e.g., FastQC could be repeated for trimmed and untrimmed reads.